Maison BeaulieuMAISON BEAULIEUAB ÉDITIONS · CULINARY ARTS & ARCHIVES
Cuisine · Understanding

Pressure Cooker: Understanding the Link Between Pressure and Temperature

A pressure-cooker specification sheet states a pressure; a culinary explanation derives a temperature from it. Between the two, part of the reasoning is often missing. What reference does that number use? What medium are we talking about? Which relationship allows us to move from one quantity to the other? Understanding that step helps you read a technical sheet and see exactly what it allows you to calculate.

The examples that follow are numerical constructions. We choose their pressures and assumptions to explain a physical correspondence. They do not describe the measured behaviour of any appliance and provide no cooking settings.

🎁 Free Reader Gift · A4 Printable Recipe Booklet

Receive “12 Signature French Recipes & Culinary Index” (Free A4 PDF)

Instant complimentary delivery: 12 foundational French recipes, temperature & conversion charts, and a direct guide to our 240-volume English culinary library.

Starting from a defined pressure

The manufacturer’s FAQ lists a high-pressure range of 10.2 to 11.6 psi. The lines consulted do not specify whether that reference is absolute or gauge. We therefore do not convert those figures into a temperature. Nor does a stated range turn into an exact point simply because one applies a more detailed calculation to it.

To build our example, let us instead choose an ambient pressure of 100 kPa and an inside–outside difference of 80 kPa. By definition of that difference, the absolute interior pressure is 180 kPa. The 80 kPa figure is our own exercise choice; it does not translate the psi values from the FAQ. Every pressure used from here on to match a temperature will be an absolute pressure.

Next, let us change a single input: ambient pressure is 80 kPa, while the chosen difference remains 80 kPa. The interior pressure becomes 160 kPa. The same pressure difference therefore leads to two different points on the curve we are about to read. This calculation assumes the difference stays identical in both situations; it does not claim that a commercial appliance automatically maintains that condition.

Reading a saturation curve

The IAPWS Industrial Formulation, Region 4 relates pressure and temperature along the liquid–vapour coexistence curve of pure water.

Conversion. Calculations performed in absolute temperature; values displayed in degrees Celsius.

Within this framework, 160 kPa corresponds to about 113.3 °C and 180 kPa to about 116.9 °C. Return to our two chosen situations: their inside–outside pressure difference was identical, yet the calculated temperatures differ by roughly 3.6 degrees. To reach that result, we first added the pressures according to our definition, then applied the saturation relation. Reversing those two steps would not pose the same problem.

One can also work from a target pair in an exercise. Suppose a worksheet pairs 180 kPa with 116.9 °C. That pair is consistent with our calculation for pure water on this curve. If the same sheet keeps the temperature while replacing the absolute pressure with 160 kPa, the two numbers no longer name the same point. To fix the exercise, you must choose which value is held fixed and recalculate the other. Adding decimal places to both numbers does not restore their correspondence.

We have introduced no food, no piece size, and no cooking time into this calculation; none of those quantities can therefore emerge from it. An explanation of the physical link can be exact within its own domain while remaining insufficient to decide how many minutes a dish requires.

Evaluating what an extra increment of pressure changes

The calculated relation lets us compare two equal increases. Between 100 and 120 kPa, temperature rises from about 99.6 to 104.8 °C—a gain of 5.2 degrees. Between 180 and 200 kPa, it rises from about 116.9 to 120.2 °C—a gain of 3.3 degrees. In both exercises we add 20 kPa, yet the temperature gains are not equal.

To picture this comparison, imagine two short segments laid on a graph. The first joins the points calculated for 100 and 120; the second joins those for 180 and 200. Both share the same width along the pressure axis, yet their heights differ. A rule assigning the same temperature gain to every 20 kPa step could not pass through all four points at once. You would have to choose the neighbourhood in which that approximation is acceptable.

Take a narrower interval, from 160 to 180 kPa. To estimate the temperature halfway between, you might average the two endpoint temperatures, giving about 115.105 °C. Direct calculation at 170 kPa gives about 115.149 °C—a gap of only 0.044 degrees in this example. That small discrepancy explains why linear interpolation can yield a practical estimate close to the exact value without itself being the underlying relation.

How you round then depends on the question. If we present these results to one decimal place, the average reads 115.1 and the direct calculation reads 115.1 as well. Rounding hides their difference here; it does not prove that the curve is a straight line. If we wished to explain the shape of the relation, we would keep the intermediate digits; if we only wanted to place a point within that interval, one decimal place might suffice for our example.

Another comparison would be misleading: dividing the displayed temperatures by the pressures in search of a constant ratio. For the two points at 160 and 180 kPa, the resulting quotients are not the same. Nothing in our calculation imposes such proportionality. Before adopting a shortcut, you must know which operation it replaces and inspect the error it produces over the interval actually chosen.

Making room for a second gas

A more important distinction remains than the last tenth of a degree. If another gas contributes to the pressure, can you still feed the entire pressure into the pure-water relation? The Gross report sets out PV=nRT and the addition of partial pressures for a homogeneous ideal mixture.

Let us build an approximate model from those relations. Assumptions: pure water with liquid present; a shared temperature; a second ideal gas in fixed amount occupying a fixed gas volume. For the water-vapour contribution, we take as an approximation the saturation pressure of pure water at that temperature. This construction is not an exact equation of a real mixture; it isolates the role of the second contribution.

Write Pₛ(T) for the calculated saturation value. For the other gas, gather the constants into a coefficient a=nR/V. Its contribution then reads aT, with T in kelvins. We choose a=0.1 kPa/K. That number is an invented parameter for the exercise, not derived from an actual pot. To reach a total of 180 kPa, we must now solve Pₛ(T)+aT=180.

First try a temperature of 110 °C, or 383.15 K for this calculation. The calculated water contribution is about 143.376 kPa. The other term is 0.1 multiplied by 383.15, or 38.315 kPa. Adding them yields 181.691 kPa—slightly too high for our chosen total.

Solving the equation gives about 109.654 °C. At that temperature, the first contribution is 141.720 kPa and the second is 38.280 kPa; their sum equals 180 to the stated rounding. That result sits below the 116.912 °C calculated when the extra contribution was absent. We kept the same total pressure and changed how it is shared between the two terms.

Three splits of 180 kPa between the two terms of the model.
Examples from the text, with a in kPa/K.

Had we simply plugged 180 in as the water-vapour pressure and then added 38 kPa for the other gas, we would have exceeded the imposed total—a contradiction within the model’s construction. To hold the total at 180, the water contribution must leave room for the other term, and the temperature we are solving for shifts under that constraint.

Finding a temperature that closes the sum

We can locate the solution without starting from the answer. At 109 °C, the calculated sum is about 176.841 kPa; at 110 °C, it is 181.691 kPa. Our target of 180 lies between the two. At 109.5 °C, we obtain 179.250 kPa—still too low—so we continue searching in the upper half of that narrow interval. At 109.65 °C, the total is 179.979 kPa; at 109.66 °C, it is 180.027 kPa. These checks bracket the solution to the hundredth of a degree on the rising stretch of our function.

A second way of calculating highlights the coupling between the two contributions. Start provisionally at 116.912 °C, the no-second-gas result. The extra term evaluated at that temperature is about 39.006 kPa. Subtract it from 180 to see how much room remains for water; the new temperature matching that room is about 109.502 °C. Because we evaluated the subtracted term at the old temperature, we now have to update it.

At this new temperature, the extra contribution is about 38.265 kPa. Another subtraction and lookup give about 109.658 °C; repeating once more gives about 109.654 °C. The values close in on the solution verified earlier. That numerical path works for the chosen example; we do not present it as a guarantee of convergence for every mixture or every equation.

Both searches address one specific point: the split of the 180 kPa depends on a temperature that is itself unknown. Subtracting a contribution evaluated once at an arbitrary temperature leaves that link incomplete. The first method adjusts the total directly until it hits the target; the second updates both contributions in turn.

Understanding the chosen coefficient

Now choose a=0.05 kPa/K, half our first value, keeping the total fixed at 180. The calculated solution is about 113.425 °C, with the two contributions at roughly 160.671 and 19.329 kPa. The second term is not exactly half of the earlier 38.280: the coefficient was halved, but the solution temperature shifted too. Both new values must be used together to check the sum.

Consider also the limiting case a=0. The equation then requires the first contribution alone to supply all 180 kPa, recovering the pure-water result of about 116.912 °C. That check links the two exercises: the two-term model contains the first as its limit, and also shows where a missing term would show up in a sum.

Tracking what moves from liquid to vapour

In the previous model, we chose the second gas’s coefficient directly. Now specify a full initial state to determine it: a temperature of 300 K and a total pressure of 100 kPa. We keep the same gas volume, the same fixed amount of extra gas, and sufficient liquid water. Water may divide between liquid and vapour, with its total amount conserved. Those are the conditions of our new exercise.

At that starting temperature, calculation gives 3.537 kPa for the water contribution, leaving about 96.463 kPa for the other gas. Dividing that remainder by 300 fixes our coefficient at about 0.321545 kPa/K. We are no longer tuning the coefficient to hit a chosen final temperature; we have fixed it from the starting state and must carry it unchanged into the search for the next state.

Let us find the state matching a total of 180 kPa under these conditions. The solution is about 360.743 K, or 87.593 °C. The two contributions are then roughly 64.005 kPa for water and 115.995 kPa for the other gas, together supplying the required 180 kPa. This result differs again from those obtained with our earlier chosen coefficients: the initial state locked in a different split, which we carried through the calculation.

Compare how the two contributions change. For the extra gas, the pressure ratio is about 1.2025—matching the ratio of 360.743 to 300. For water vapour, the pressure ratio is far larger: about 18.10. The same temperature rise shared by both components therefore cannot explain both increases by a single common multiplier. In our construction, something else changes for the vapour.

To compare amounts, we treat the vapour as ideal as well—an added approximation beyond the mixture model, not an exact density of real steam. In this accounting, the amount of each component is proportional to its pressure divided by temperature, since both volume and the gas constant stay fixed. The ratio of vapour amounts is thus the ratio of 64.005/360.743 to 3.537/300. Using the unrounded calculation values, that ratio is about 15.05.

The amount of extra gas thus remains constant while the amount of vapour multiplies by roughly fifteen in this exercise. Liquid water supplies the difference. Total water across both phases stays conserved; only its distribution shifts. By contrast, the total amount of gas in the vapour space increases because it receives water from the liquid. Closing the model to outside exchange therefore does not by itself hold the amount of gas inside constant.

Test the opposite assumption to see what happens. If we held the total amount of gas constant in the same volume, proportionality between pressure and temperature would take 300 K to 540 K as pressure rose from 100 to 180. Yet at 540 K, our pure-water calculation already yields a saturation pressure of roughly 5,237 kPa—vastly above 180 even before adding any positive term for the second gas. That result cannot simultaneously satisfy the conditions chosen for the final state.

The contradiction arises from holding total gas amount fixed while our other assumption lets liquid feed the vapour. One must pick a consistent description and stick to it throughout. The 87.593 °C solution belongs to the approximate model with liquid present, fixed gas volume, and phase exchange; it does not name a boiling temperature to ascribe to an actual pressure cooker.

Finally, we can check what “sufficient liquid” means without prescribing how much water to pour into a pot. Normalise the initial amount of vapour to one unit. The calculated final amount is then about 15.05 units, meaning the liquid must have supplied about 14.05 units while still remaining present. With 20 initial units of liquid in this abstract tally, roughly 5.95 units remain. With only 10, the calculated final state would demand more liquid water than the model contains.

In that last case, we must abandon that final state under those assumptions. We neither stay on the same curve pretending liquid remains nor compute here a state after dry-out. The test clarifies the condition under which the model holds, and shows why a pressure and a temperature alone do not specify the complete state of a system where water can change phase.

Testing a pressure–temperature pair

One can flip the question without guessing an amount of gas. In the same approximate model, take 180 kPa and 110 °C as a starting pair. Calculating the water contribution gives 143.376 kPa, leaving 36.624 kPa. Dividing that remainder by 383.15 K yields a coefficient of about 0.09559 kPa/K. With that choice, the proposed pair can satisfy our equation.

Now try another pair to test the reasoning: still 180 kPa, but 120 °C. At that temperature, the calculated contribution for pure water is about 198.665 kPa—already above the total available. The remainder would be negative: minus 18.665 kPa. Carrying out the division would produce a coefficient near minus 0.04748 kPa/K. A negative coefficient is incompatible with a positive or zero amount of extra gas in our construction.

The value of this result is that it pinpoints the contradiction before blaming an appliance. The two figures cannot belong simultaneously to our model with a non-negative coefficient. That does not prove a real measurement at those values would necessarily be wrong: it could reflect another state, another medium, or a non-equilibrium situation. What the calculation has just tested is the consistency of the full set of assumptions.

Within this model and across the range examined, the case with no extra contribution thus sets the upper temperature limit compatible with the chosen total. Any positive contribution claims part of the available pressure; to keep the total fixed, the water term must be smaller than in the limiting case. Both solutions computed with positive coefficients indeed fall on the expected side. We now have a direction check alongside the numerical check by addition.

When reading a pressure-cooker explanation, keep in mind which question each step answers. A defined pressure sets the entry point of the calculation. A mixture model requires sharing the pressure among its components. The temperature of a food and the timing of a recipe require further information. A technical explanation becomes far more useful when it shows that bridge along with its conditions, rather than asking a single printed number to carry the entire argument.