Maison BeaulieuMAISON BEAULIEUAB ÉDITIONS · CULINARY ARTS & ARCHIVES
Cooking · Bread

Bread Water Temperature: Calculating the Formula and Determining the Friction Factor

A recipe gives a target dough temperature to reach at the end of mixing. Water then becomes a setting to choose, rather than a vague instruction such as “lukewarm.” Yet the calculation often includes a friction factor whose name sounds simpler than its use. Before adopting a number found in a guide, you need to understand how that number was determined and in which equation it will be used.

The numerical data that follow are constructed to explain this method. They do not report any mixing carried out by the editorial team. The target temperatures serve the calculations; they do not constitute a recommended range for all doughs.

🎁 Free Reader Gift · A4 Printable Recipe Booklet

Receive “12 Signature French Recipes & Culinary Index” (Free A4 PDF)

Instant complimentary delivery: 12 foundational French recipes, temperature & conversion charts, and a direct guide to our 240-volume English culinary library.

Calculating Water Temperature With Three Factors

The professional reference from King Arthur Baking uses, without a preferment, the relation: water = 3 × target − air − flour − r.

Let us set a target of 25 °C, air at 22 °C, flour at 23 °C, and a factor r of 9 on the Celsius scale. The calculation gives 3 × 25 − 22 − 23 − 9 = 21 °C for the water. The result is not the temperature of water we measured. It is the value required by the rule given the four chosen numbers.

The multiplier 3 applies to the target before the subtractions. If the target rises by one degree while the other inputs stay fixed, the calculated water setting therefore rises by three degrees: 3 × 26 − 22 − 23 − 9 = 24 °C. If only the flour goes from 23 to 25 °C, the calculated water temperature drops by two degrees, to 19 °C. Those variations belong to the equation being used; they do not separately measure how a real dough would respond to each change.

That gives a precise way to redo a calculation when conditions change. The 21 found at the start does not remain a setting permanently attached to the name of the bread. It also depends on the inputs on the sheet. You can keep the same target while getting a different water temperature, or keep the same water temperature under different conditions and a different target. You must therefore keep the data that produced the result together, rather than turning the isolated number into a standing instruction.

Recovering the Factor From a Final Result

Now let us recover r from a hypothetical final result. Suppose the water was at 21 °C, with air at 22 and flour at 23, but the dough was recorded at 26 °C at the end.

This time we solve for r. The relation gives r = 3 × 26 − 22 − 23 − 21, which equals 12. This is not a three-degree correction added to the previous water temperature. It is the new value of the parameter in the equation, obtained from the stated final result.

With this parameter of 12 and a target still set at 25 °C, the calculated water becomes 3 × 25 − 22 − 23 − 12 = 18 °C. The one-degree gap between the earlier target and the final result here leads to subtracting three degrees from the water setting. The relation can be checked in reverse: (22 + 23 + 18 + 12) / 3 returns 25.

One mistake would erase the entire point of the exercise: plugging the target of 25 back in instead of the final result of 26. You would then get r = 3 × 25 − 22 − 23 − 21 = 9, the exact starting factor. The sheet would seem to confirm what it had assumed, because the new information would never have entered it. In this specific case, the choice of which number gets multiplied determines whether you actually used the reading.

A Calculation Residual Versus a Measured Rise

The factor we just obtained is not defined by a simple subtraction between the start and end of mixing. That other way of describing friction nevertheless appears in Maurizio Leo’s article: for a mixer, he suggests recording temperatures before and after mixing, then taking their difference. He also distinguishes the target dough temperature from the recorded final temperature. The two texts therefore do not give the exact same operation for determining the number called friction.

Let us add a hypothetical piece of data to our case: suppose the dough is at 22 °C at the start of mechanical mixing and 26 °C at the end. The rise between those two moments would be four degrees. The residual obtained with the previous equation stays 12, since none of its terms changed. Moreover, the starting temperature of the mechanical mixing phase does not even appear among the inputs of that equation.

We thus have two numbers for two distinct calculations. The first summarises a difference between two moments. The second fits a relation between a final result and several preparation temperatures. The fact that both use vocabulary linked to heating does not make them interchangeable inside a formula.

If we replace 12 with 4 in our water calculation for a 25 °C target, we get 3 × 25 − 22 − 23 − 4 = 26 °C instead of 18. The eight-degree difference comes from the substituted parameter, not from a new assessment of the dough. To adopt a published method, the useful question is therefore which operation produced the required factor. An extra measurement does not replace a missing definition.

Nor does 12 represent twelve degrees of heat that we isolated inside the motor. It was calculated from all the stated inputs. Our example provides neither a physical heat balance of the mix nor a separate measurement of the causes of its warming.

Switching to Fahrenheit Without Changing the Problem

NIST distinguishes between converting a temperature and converting a temperature interval. For a temperature, the Fahrenheit value equals 1.8 times the Celsius value, plus 32. For an interval, only the factor 1.8 applies. Exact NIST conversions

Let us convert the first case as a whole. The 25 °C target becomes 77 °F, air at 22 °C becomes 71.6 °F, and flour at 23 °C becomes 73.4 °F. The factor r of 9 here becomes 16.2 on the Fahrenheit scale. We will see why it does not receive the +32 offset applied to the three temperatures.

Water is then calculated as: 3 × 77 − 71.6 − 73.4 − 16.2 = 69.8 °F. Converting that result back gives (69.8 − 32) / 1.8 = 21 °C. We recover the exact same calculated water temperature, not a second setting meant for a different preparation.

That verification requires converting all inputs together. Keeping the factor 9 while subtracting temperatures already expressed in Fahrenheit would give 77 °F for the water. The formula would still run, but one of its numbers would not have followed the change of scale. Converting the final result afterward would not repair that mix of units.

The Offset of 32 Does Not Apply to the Factor

To see the difference, take any two temperatures separated by nine degrees Celsius. Each receives the same +32 offset when converted to Fahrenheit. When you subtract one from the other, those two offsets cancel out. The interval therefore becomes 1.8 × 9 = 16.2 degrees Fahrenheit, with no 32 added.

In the expression for r already used, switching to Fahrenheit introduces three times 32 in the first term and three times 32 in the subtracted temperatures. Their difference is zero: everything left is multiplied by 1.8. The residual therefore transforms like an interval.

Water temperature does not sit in the same position in the equation. In its forecast formula, the target term brings in three offsets of 32, while the known air and flour temperatures remove two. The factor r adds no offset at all. Exactly one 32 remains in the result—just what is needed for a water temperature expressed in Fahrenheit.

Here is the mistake that distinction prevents. Starting from r = 16.2 in the Fahrenheit calculation, someone treats it as an absolute temperature and computes (16.2 − 32) / 1.8. They get roughly −8.78 instead of 9. Fed back into the Celsius case, that number would give 3 × 25 − 22 − 23 − (−8.78), or about 38.78 °C for the water. The right result was 21 °C.

The error on the water thus approaches 17.78 degrees. It comes from the 32 wrongly subtracted and then divided by 1.8. It is neither a quirk of the mixer nor a flour effect discovered by our case. The transformation applied to the parameter changed the problem before the water was even drawn.

With a Preferment, the Parameterisation Changes

With a preferment, the same reference adds its temperature and uses a multiplier of 4. Let us keep that convention for a new constructed case: target 24 °C, air 23, flour 22, preferment 26, and factor r equal to 8.

The water called for by this relation is 4 × 24 − 23 − 22 − 26 − 8 = 17 °C. If our hypothetical reading after mixing turned out to be 25 °C, the recalculated factor would be 4 × 25 − 23 − 22 − 26 − 17 = 12. To return to the target of 24 within the same framework, the new setting would be 4 × 24 − 23 − 22 − 26 − 12 = 13 °C.

Here the multiplier gives a different sensitivity to the final result. The one-degree gap in the case leads to a four-degree correction in calculated water, from 17 to 13. In the first case without a preferment, a one-degree gap led to a three-degree correction. We are comparing two calculation rules and their inputs, not two experimental measurements of a mixer’s thermal response.

Scale conversion remains consistent with this parameterisation. When solving for r with four factors, four offsets of 32 appear in the final-temperature term and four in the subtracted temperatures. They cancel out again. When forecasting water, one still remains after the three known temperatures. Adding a preferment therefore does not turn the factor into an absolute temperature to be converted with a +32 offset.

A Single Reading Can Hide the Wrong Formula

Let us use the same data from this second case to examine an omission. The stated final temperature is 25 °C, with air at 23, flour at 22, preferment at 26, and water at 17. The four-factor relation gives r₄ = 12. If you forget the preferment and still fit a three-factor relation, you get r₃ = 3 × 25 − 23 − 22 − 17 = 13.

The 13 on that last line is a fitted parameter, not the water temperature found earlier in the right calculation. Both relations can reproduce the reading used to fit them. With r₃, (23 + 22 + 17 + 13) / 3 gives 25. With r₄, (23 + 22 + 26 + 17 + 12) / 4 also gives 25. Recovering that number is therefore not enough to prove you chose the right relation.

The difference reappears as soon as the request changes. For a 24 °C target, the three-factor relation fitted this way would give 3 × 24 − 23 − 22 − 13 = 14 °C for the water. The four-factor relation prescribed for this setup gave 13. Agreement on the initial reading masked the change in parameterisation; it had not fixed it.

We can make the source of the gap between the two parameters explicit. Subtracting their expressions yields r₄ − r₃ = final temperature − preferment temperature. In our case, 25 − 26 equals −1, which matches 12 − 13. That identity holds for the two formulas fitted to this dataset. It does not supply a permanent coefficient for converting every three-factor sheet into a four-factor sheet.

Can Two Readings Share the Same Factor?

Let us return to the constructed reading that gave r = 12: air at 22 °C, flour at 23, water at 21, and final dough at 26. Add a second, equally fictional reading: air at 24, flour at 24, water at 18, and final dough at 28. On this second row, the calculation gives 3 × 28 − 24 − 24 − 18 = 18. We thus obtain two different parameters. Should we keep two rows or look for a shared number? To answer, let us first examine what such a number could actually reproduce.

The sum air + flour + water equals 66 in both rows. Any shared factor r would therefore yield the exact same final forecast: (66 + r) / 3. Yet the two stated results are 26 and 28. No choice of r can turn a single forecast into both numbers at once. With 12, we get 26 in both cases: the first is reproduced, while the second is missed by two degrees on the low side. With 18, we get 28 in both cases: the second is reproduced, while the first is missed by two degrees on the high side.

Now choose a different objective: give equal weight to both final errors and minimise the sum of their squares. That is our choice for comparing these rows, not a tuning method recommended by the authors cited. A factor of 15 gives a forecast of 27 for each row. The errors, calculated as forecast minus stated result, are then +1 and −1 °C. Their sum is zero, which does not mean both results were recovered. Their squares add up to 2 °C². With 12 or 18, that same sum was 4 °C².

We can verify that 15 really is the best choice for this objective, rather than picking it merely because it sits in the middle. Write any candidate in the form 15 + d. Its shared forecast becomes 27 + d / 3. The errors are 1 + d / 3 and −1 + d / 3. Expanding their squares and adding them together cancels the opposite-sign terms, leaving 2 + 2d² / 9. That quantity is minimised when d equals zero. As soon as you move away from 15, the extra term is positive. We have found a compromise defined by an explicit rule, without thereby producing a third mixing record.

The compromise matches neither of the two rowsFictional data. With parameter 15, both forecasts equal 27 degrees Celsius. The stated final temperature is 26 for A and 28 for B; forecast-minus-stated errors are +1 and -1.Un paramètre commun : 15Ligne ALigne BDonnée : 26 °CDonnée : 28 °CPrévision : 27 °CPrévision : 27 °CÉcart : +1 °CÉcart : −1 °CDeux erreurs opposées restent deux erreurs.
Comparison constructed from the two fictional rows in the text. The compromise gives the same forecast without matching either final temperature.

Another objective can be solved on the same rows: making the largest absolute error as small as possible. The two errors always stay two degrees apart, whatever the shared forecast. They therefore cannot both be strictly smaller than one degree in absolute value. The pair +1 and −1 reaches that limit. In this symmetric case, the same factor 15 satisfies both objectives. Our demonstration does not say they always pick the same number for other sets of readings.

That choice has a consequence for the water temperature calculated next. With a target of 25 °C, air at 22, and flour at 23, factor 12 gives 18 °C for the water; the compromise 15 gives 15 °C; factor 18 gives 12 °C. The sheet can therefore propose three different settings depending on the chosen parameter. Using 15 means accepting the compromise we just defined. It means neither that you reproduced both rows exactly, nor that you know which row describes the conditions of the next mix.

Finally, let us ask whether the two readings could become compatible by allowing a margin on their final temperature alone. For this reasoning, the other three temperatures are treated as exact. Let us arbitrarily set a margin of 0.5 °C on either side of each result; that is not the stated accuracy of any thermometer. The first final temperature can then range from 25.5 to 26.5 °C, giving a factor between 10.5 and 13.5. The second can range from 27.5 to 28.5, giving a factor between 16.5 and 19.5. The two intervals do not meet: no shared factor satisfies that requirement.

Widening the stated margin to one degree turns the first factor range into [9; 15] and the second into [15; 21]. They touch at 15 alone. The shared final temperature of 27 then sits at the upper bound of the first temperature range and the lower bound of the second. The compatibility obtained comes from a relaxed condition. It does not prove that the initial readings actually contained that error, nor does it assign any probability to their accuracy.

Those two rows are thus enough to separate three accounts: two separate fits that each recover their own row; a shared compromise accompanied by explicit errors; and a shared factor admissible under chosen bounds. Moving from one to another changes what the sheet claims. The gap between 12 and 18, on its own, points neither to a physical cause nor to a change of mixer. Here it shows what a single number can—and cannot—represent in the data at hand.

Keeping the Conditions With the Number Obtained

King Arthur Baking lists mixer type, mixing time, speed, and batch size among the variables affecting the factor.

To read an existing sheet, three details can suffice: which relation does it use, how was the parameter determined, and on what scale is it expressed? Our first case called for 18 °C after recalculation, the second for 13 °C. Those results remain tied to their data and their rules. They are not two recipe temperatures to be reused without their context.