The dataset constructed for this article will not always give the diameter of every individual particle. We will examine two known sizes first, then see what remains calculable once individual values are replaced by size classes.
Malvern Panalytical distinguishes particle size distributions by number and by volume.
Receive “12 Signature French Recipes & Culinary Index” (Free A4 PDF)
Instant complimentary delivery: 12 foundational French recipes, temperature & conversion charts, and a direct guide to our 240-volume English culinary library.
We will work with constructed geometric objects: solid spheres 200 and 1,000 micrometers in diameter. They are neither photographed coffee grounds nor grinder measurements. Their surface area is simply their outer area, without pores. We will speak of equivalence between mass and volume only under the assumption of uniform density. These choices keep the arithmetic verifiable; they do not assign real coffee a shape or density we have observed.
One hundred particles are not one hundred equal shares of volume
The first batch, A, contains ninety small spheres and ten large ones. By count, the small spheres make up 90% of the objects. The diameter that splits this count in half sits inside the 200-micrometer group: once sorted by size, both the fiftieth and fifty-first particles belong to that group.
Now switch to volume. A large sphere has five times the diameter of a small one, so its volume is five times five times five—one hundred and twenty-five small volumes. You can check this with the formula for the volume of a sphere, π times the diameter cubed divided by six. Because the factor π/6 is shared by both sizes, it cancels out when taking their ratio. What remains is the cube of five, not five itself.
Take the volume of one small sphere as our unit. The ninety small spheres contribute ninety units; the ten large ones contribute 1,250. The total is 1,340. The volume fraction of the small spheres is therefore 90/1,340, or roughly 6.72%—even though they made up 90% of the count. Saying “nine out of ten particles are small” was accurate; translating that into “nine-tenths of the volume is fine” would dramatically overstate their share of the batch.
In this example, reaching half the total volume forces us into the large-sphere group. Let us call the number-weighted median diameter Dn50 and the volume-weighted median diameter Dv50. Batch A thus gives 200 micrometers for Dn50 and 1,000 for Dv50.
For percentiles in our two-size lists, we adopt the first diameter whose cumulative share reaches the target percentage. This is a discrete convention, with jumps between two groups; we are not reconstructing software interpolation across instrumental bins. That rule will prove decisive when a group hits exactly half the volume.
Two batches with the same medians can hold different fine fractions
Build a second batch, B, keeping ten large spheres while raising the number of small spheres to 990. Small spheres now account for 99% of the count. Their combined volume is 990 units, still alongside 1,250 units from the large spheres, so they occupy 990/2,240 of total volume—about 44.20%. Yet both medians stay unchanged: 200 by count and 1,000 by volume.
Another percentile distinguishes the two batches here. To reach 10% of batch A’s volume, the small spheres alone are not enough, so Dv10 is still 1,000 micrometers under our convention. In batch B, the small spheres easily exceed 10%, so Dv10 drops to 200. Dv90 remains 1,000 for both.
Surface area introduces yet another weighting
The outer surface area of a sphere is π times the square of its diameter. A large sphere therefore has twenty-five times the surface area of a small one, compared with one hundred and twenty-five times its volume. Taking one small surface area as our unit, batch A has ninety units from small spheres and 250 from large ones. The small spheres’ share of total surface area is 90/340, or about 26.47%—sitting right between their number share and their volume share.
For batch B, the same calculation gives 990 units for the small spheres and 250 for the large ones, bringing the fraction to 990/1,240, or about 79.84%. This batch still has a Dv50 of 1,000, while assigning nearly four-fifths of its ideal outer surface area to the small group. The volume median alone cannot recover how that surface area is distributed.
Batch A: 90 small, 10 large
Batch B: 990 small, 10 large
Diagrams calculated for this article.
One trap remains when comparing total surface areas. Our two raw batches do not have the same volume: A contains 1,340 small-sphere units, while B contains 2,240. Comparing their raw sums of surface area would not answer the question “what do two equal amounts of material yield in this model?” We have to choose that normalization first, rather than treating the two lists as equal doses merely because each has a name.
The ratio of total surface area to total volume provides that comparison. For spheres, the geometric factors reduce to six times the sum of squared diameters weighted by their counts, divided by the sum of cubed diameters weighted by those same counts. For A, that gives roughly 0.007612 inverse micrometers; for B, roughly 0.016607. The unit is area divided by volume—the reciprocal of a length—not a surface area in square micrometers.
For two equal total volumes, the ratio of B’s surface area to A’s is simply the ratio of those two figures, roughly 2.18. We corrected for the difference in total amount before comparing. Even so, this ideal outer surface area describes neither internal pores nor how water flows through a coffee bed.
A size class does not reveal every diameter inside it
Now switch to a different dataset. This new constructed tally reports ninety particles from 100 micrometers inclusive to 200 exclusive, and ten from 200 to 1,000 inclusive. The classes do not overlap: a 200-micrometer particle belongs to the second class. This is therefore not simply a binned version of batch A, whose small spheres measured exactly 200. The counts look familiar, but the information received and the allowable diameters are different.
One compatible population consists of ninety spheres of 110 micrometers and ten of 990. The diameter ratio is nine, making the volume ratio 729. The first group thus represents 90/(90 + 10 × 729) of total volume, or 1/82—about 1.22%—and the volume median is 990. Every particle sits squarely inside its stated class; nothing in the binned tally ruled out such overwhelming volume dominance by the second group.
Another compatible population consists of ninety spheres of 190 and ten of 210. Here the first group contributes 90 × 190³ volume units and the second 10 × 210³, sharing the same geometric factor. The first group’s share becomes 6,859/7,888, or about 86.95%, and the volume median is now 190. Yet both populations produce the exact same counts in the exact same bins. The conversion is not missing particles; it is missing their positions inside each class.
Replacing those unknown positions with class midpoints does not restore the missing data. Doing so assigns 150 to the first ninety spheres and 600 to the other ten. The individual volume ratio becomes 64, giving the first group 90/(90 + 640), or 9/73 of total volume—about 12.33%—with a volume median of 600. That third calculation is exact for the population we just invented, but it does not prove that population was the one measured. An interval’s midpoint does not become a measurement of every object inside it.
Intervals do, however, establish bounds. The smallest possible volume share for the first group uses its smallest allowed diameter, 100, and the largest allowed diameter in the second group, 1,000. A 1,000-micrometer sphere holds one thousand volumes of a 100-micrometer sphere, since its diameter is ten times larger. That minimum share is 90/(90 + 10 × 1,000), or 9/1,009—about 0.89%—and it is actually attained by those choices. To see why no valid choice can go lower, notice that increasing the volume of any sphere in the first group raises its share of the total, whereas increasing a sphere in the second group lowers it; both chosen extremes push toward the minimum.
At the opposite extreme, the first spheres can approach 200 from below while those in the second group equal 200. Individual volumes become nearly identical, so the first group’s share approaches 90/100, or 90%. It remains strictly below that limit because the first interval excludes 200; no allowed population actually attains this upper bound. We therefore have an attained minimum and an approached upper limit, not two symmetrically realized endpoints.
A binned tally thus does not let us treat the midpoint estimate as forced by the data. Under our assumptions, it permits a volume median in the first group just as readily as one in the second. The bounds reflect what the classes genuinely state, whereas the three illustrative populations show what we add when we pick specific diameters. No continuous curve between those diameters has been measured or reconstructed.
Same tally, different volumes
Using midpoints is a substitution assumption, not a measurement of diameters.
Diagrams calculated for this article.
A bar’s height depends on what it is meant to represent
Take another dataset, independent of the earlier ones: forty particles in the class from 100 inclusive to 200 exclusive, and sixty in the class from 200 to 1,000 inclusive. If the vertical axis shows the count in each class, bar heights of forty and sixty are completely valid: the second bar is taller because that class holds more objects. Yet notice that its diameter interval is eight times wider—eight hundred micrometers versus one hundred.
Now choose a different plotting convention: let the area of each rectangle represent its class count on a horizontal axis scaled linearly in micrometers. The first height must be 40/100, or 0.4 particles per micrometer; the second must be 60/800, or 0.075. Their areas recover 0.4 × 100 = 40 and 0.075 × 800 = 60. This time, the first bar is taller—it represents fewer objects overall, packed into a far narrower interval.
We neither added particles nor swapped the two classes. We changed what height means: count per class in the first chart, count per unit width in the second. If someone kept heights of forty and sixty while reading areas as counts, the area ratio would be 4,000 to 48,000, or one to twelve—nowhere near the true two-to-three count ratio. The error lies in reading areas where none were meant, not in plotting a chart that honestly labels its counts per class.
The horizontal axis can change too. Define a dimensionless coordinate u = log10(d / (100 µm)), where d is the diameter. A diameter of 100 maps to zero, 200 maps to log10(2)—roughly 0.30103—and 1,000 maps to one. The two bin widths become roughly 0.30103 and 0.69897. One whole unit along this axis corresponds to multiplying the diameter by ten, not adding a fixed number of micrometers.
To keep forty and sixty as the areas in this new coordinate system, the average rectangle heights become 40/0.30103 and 60/0.69897, roughly 132.877 and 85.841, now expressed as count per unit of u. Using exact unrounded values restores areas of forty and sixty. The previous heights of 0.4 and 0.075 were expressed per micrometer; multiplied directly by the new widths, they would not yield those counts.
One can still choose to plot per-micrometer values above a logarithmic horizontal axis, as long as they are labeled that way; what does not automatically carry over is reading visual areas as counts. Meanwhile, our new constant heights are class averages computed for this coordinate—they do not recover a continuous density inside each bin. This example does not recreate the vertical axis of any cited manufacturer’s curves; it simply constructs two explicit ways of displaying the exact same forty and sixty objects.
Widths in micrometers
Widths in the logarithmic coordinate
u = log10(d / (100 µm)). Heights per micrometer and per unit of u carry different units.
Diagrams calculated for this article.
What escapes detection can shift the full median
In an April 2019 discussion published on Coffee ad Astra, the author of the grind-distribution app notes that his software directly measures projected area, while its volume and mass estimates rely on assumptions; he also points out the detection limit for particles smaller than a pixel. These are dated explanations from the author, not our own evaluation of an installed program or a current camera.
For this separate exercise, return to the 200- and 1,000-micrometer spheres from the beginning. To see the effect of non-detection, imagine an instrument that logs only objects of at least 300 micrometers, given no total mass or any other information about ignored objects. On batch A, it records the ten large spheres and misses all ninety small ones. The visible tally gives a median of 1,000 by both count and volume, even though the full number median would have been 200.
Now construct a possibility C with 2,000 small spheres and the exact same ten large ones. The imaginary instrument returns the exact same list of ten diameters of 1,000. Yet in the full batch, the small spheres account for 2,000/(2,000 + 1,250), or about 61.54% of the volume, making Dv50 equal to 200 for C where it was 1,000 for A. The identical list of detected objects is thus compatible with two different full-batch volume medians.
The tipping point can be computed without inventing a third median. The ten large spheres always weigh in at 1,250 small-sphere volumes, so it takes 1,250 small spheres for their group to match that volume. With 1,249, their share stays below half and Dv50 remains 1,000. With 1,250, cumulative volume hits half right at 200, so our convention returns 200. Stating that rule upfront avoids substituting an intermediate diameter absent from the list.
The list of ten detected objects therefore does not prove that the hidden fraction is small. If that list is the sole piece of information kept, adding ever more small spheres can push their volume share arbitrarily close to 100%. There is of course a domain ceiling—a fraction cannot exceed 100%—but what is missing is an informative upper bound below that ceiling. A known total mass, a count cap, or another measurement would add a real constraint; none was given to our imaginary device.
The 300-micrometer threshold belongs solely to this thought experiment; it is not a resolution attributed to the app or to any camera.
Merging four objects creates a different kind of error
Non-detection drops objects from the tally. Merging, by contrast, can preserve their total projected area while changing their identity in the calculation. Picture four small spheres 100 micrometers in diameter, seen as four non-overlapping disks. In this scenario, we mistakenly group those four projections under the label of a single object. That mistake is our own hypothetical setup; it does not describe how the Coffee ad Astra app actually processes images.
Each disk has an area of π times fifty squared, so all four together give 10,000π square micrometers. A single disk of diameter 200 has that exact same area. Its diameter is therefore an area-equivalent diameter—not the widest span across the cluster, nor the diameter of a circle enclosing all four disks. The equality applies strictly to the preserved sum of areas.
If the next step converts that merged object into a 200-micrometer sphere, it assigns it eight times the volume of a 100-micrometer sphere: doubling the diameter multiplies volume by eight. Yet the four stipulated spheres actually supplied only four such volumes. The final estimate is double the true volume defined in our model, even though total area never changed between the two descriptions.
You can check the gap by keeping the two operations separate. Converting each of the four 100-micrometer diameters to volume first and then summing yields four units. Summing the areas first, computing the equivalent diameter of 200, and then converting that diameter to volume yields eight. Because volume conversion is not linear in area, replacing a group with a single diameter beforehand is not neutral. Matter was neither created nor destroyed; our grouping simply skewed the estimate.
The two measurement flaws therefore call for different interpretations. With a detection threshold, small objects were missing from the list. Here, their areas were counted, yet converted as though they belonged to a single sphere. Merely applying a count correction without revisiting the volume calculation would not necessarily fix this second error. Our example isolates the role of segmentation before conversion, without claiming that every clump or every piece of software produces the same factor of two.
In its application note AN186, HORIBA describes a dry dispersion setup where compressed air breaks up clumps before laser diffraction analysis. We cite that attributed sample-preparation example without endorsing any claims about superiority or flavor. A reading of dispersed particles and one that retains clumps are not necessarily examining the same units. Reading the protocol must therefore accompany reading the diameters; it does not turn our geometric calculation into a test of the instrument.
Sources and method
Malvern Panalytical, overview of particle size distributions, June 28, 2018: weighting bases and parameters. The companion guide and illustrations were not inspected.
Coffee ad Astra, presentation of the app, April 7, 2019 post and author replies: projected area, volume assumptions, and detection limits. No software or photographs were tested here.
HORIBA, note AN186, Particle Characterization of Coffee, page 2: dry preparation and deagglomeration. The full document was read; pages 2 and 3 were also inspected visually. Its curves are not reproduced.
Populations A, B, and C, thresholds, spheres, and groupings were constructed for this article. Calculations were carried out in exact rational arithmetic and verified independently. They use standard methods, claiming no new discovery and involving no measurements of coffee, cameras, or grinders.
