A needle stays in the same place, a similar amount arrives in the cup, and it is tempting to conclude that water travelled through the coffee in the same way. Before looking for another adjustment, however, one question deserves to be asked: are those observations enough to distinguish between several possible paths? We can examine this problem without promising a better drink and without assigning a flavour to a number. We need to look at what instruments measure, then build an example where the results can be checked.
In this feature, the numbers belong to imagined networks. No machine was operated and no coffee was tasted. The units in the calculations are abstract: a pressure of two is not a two-bar setpoint. The model serves to examine an inference, not to replace a machine manual or represent the full chemistry of an extraction.
Receive “12 Signature French Recipes & Culinary Index” (Free A4 PDF)
Instant complimentary delivery: 12 foundational French recipes, temperature & conversion charts, and a direct guide to our 240-volume English culinary library.
Where is the measurement taken?
Which part of the circuit does the displayed figure refer to? That question precedes its interpretation. In its 2017 presentation of the GS3, La Marzocco locates the flowmeter of the AV version on the cold side of the boiler. For the MP, the manufacturer describes a pressure gauge at the brew point rather than only in the boiler. Those details apply to the machines described in that document. They do not let you place the sensor of another machine from memory.
A measurement taken at one spot does not automatically supply all the others. To reason clearly, imagine two pressure taps, one at the inlet and one at the outlet of the object under study. We will call their difference P. The calculation that follows uses this drop between the two ends. A single gauge gives the same information only if you also know its reference and what sits between its measurement point and the ends considered. It would therefore be premature to substitute any dial reading for P.
The same discipline applies to volume. The amount counted by an upstream instrument and the amount collected in the cup occupy different places in the circuit. To equate them in a reasoning step, you would need to specify the path, the observation window, and any differences between inlet and outlet. We will sidestep that difficulty by defining in our example a shared outlet that collects exactly what passes through both branches. That equality is a stated assumption, not a certified property of every espresso machine.
Two branches and a single outlet
Let us draw two parallel paths, A and B. They connect the same inlet and outlet points, so the pressure drop P is shared. We assume steady flow, with no accumulation and fixed properties. For each branch, let us choose a proportional relation: its flow rate is its conductance g multiplied by P. The proportionality is drawn from Mo and colleagues, with the fixed constants grouped into g.
The symbols remain easy to read: g indicates how much the branch lets through in this model when P equals one unit. The total flow rate at the shared outlet is the sum of the two flows. We will compare a network whose conductances are five and five with another whose conductances are nine and one. These are choices for calculation, with no measurement of real grounds, holes, or channels.
With P equal to one, the first network yields five flow units in A and five in B. The second yields nine and one. Both shared outlets read ten. An instrument that sees only that total cannot tell which of the two networks it was given. Its reading can be accurate while the interpretation “both branches receive the same amount” is false for the second network. The issue here comes from the available information, without needing to invent an instrument error.
The shares are fifty per cent on each side in the first case, and ninety and ten per cent in the second. We are comparing only two branches. Even the first split proves no uniformity inside either branch: their description says nothing finer. If you wanted to compare zones per unit area, you would also need to specify their areas. Nor does anything in this addition demonstrate equal chemical extraction.
Case 1
Case 2
Faster does not mean differently distributed
Now let us raise P from one to two without changing the conductances. In the nine/one network, the flows become eighteen and two, or twenty in total. The first branch still receives ninety per cent of the flow. Each flow rate doubled, yet their ratio stayed the same. That conclusion follows from our common multiplier; it depends on keeping the chosen assumptions intact.
Let us stop each calculation when forty units of volume have reached the shared outlet. At P equal to one, a total flow rate of ten takes four units of time. Branch A has then delivered nine times four, or thirty-six, and B one times four, or four. At P equal to two, a total flow rate of twenty takes two units of time. The volumes become eighteen times two and two times two: still thirty-six and four.
We changed the time required to reach the final volume while keeping the split of that volume between the branches unchanged. Saying only “the flow is faster” would have left that distinction invisible. Conversely, observing the same final volume does not tell you how much time elapsed. Each piece of information answers a specific question: cumulative quantity, speed of flow, or split between paths.
Let us return to the two networks whose total conductances equal ten. For any positive value of P, each delivers ten times P at the shared outlet. Taking more global readings at different pressures still does not separate them within this family of models. You can even replace nine and one with any positive pair summing to ten: the total curve stays identical. What is missing is information capable of distinguishing the branches, not simply more points on the same curve.
Suppose now that we also know, at the same moment and still for P equal to one, the flow rate in branch A: it is six. That figure is added for our exercise. With ten at the shared outlet, four remains for B. Our chosen relation then gives gA equal to six and gB equal to four. We have determined both conductances in this model, whereas the total alone gave only their sum.
The five/five and nine/one networks are now ruled out: neither gives six in A under that same pressure drop. Yet both remained completely compatible with the total curve calculated earlier. The difference comes from where the extra information applies. Another measurement of the total at P equal to two would have given twenty for all three networks and eliminated none of them.
To see what is fixed, we can write the calculation the other way round. If A must deliver six and P equals one, its conductance cannot be nine: nine times one would give nine, contradicting the new datum. Since the two branches together deliver ten, choosing four for B is not a free adjustment made to suit the example. It is the remainder forced by the shared outlet. Under our chosen relations, we have thus narrowed a family of possible solutions down to a single pair.
What you hold constant changes the comparison
Now let us compare the nine/one network with a third one, three/one. If we hold P equal to one, the total flow drops from ten to four. That is a constant-pressure-drop comparison; it does not keep the flow rate constant. To get ten from the third network, we must choose P equal to two and a half: the first branch gives seven and a half, the other two and a half.
This time, we fixed the total flow rate and calculated the required pressure. The two imagined experiments do not answer the same constraint. Writing “everything else was identical” would hide the very variable that was allowed to change. In the first case, the outlet flow varies; in the second, the calculated pressure varies. You cannot arbitrarily fix both and ask the same network to satisfy their incompatibility.
The split of the third network is seventy-five and twenty-five per cent, whether P is one or two and a half in our model. Raising its total flow to ten therefore does not turn it into the nine/one network. You can match a global figure from the first example while obtaining a different split. That comparison is more precise than the vague idea of “compensating”: you must name what compensation restores to the target value and what it leaves different.
An upstream tap adds another unknown
Let us add an element before the two paths split. In this new example, we give it a fixed resistance R: its own pressure drop is R multiplied by the total flow rate. The overall inlet lies before this element, while the inlet to the two branches lies after it. The shared outlet remains our reference. We therefore distinguish the upstream pressure from P, the drop across the branches.
Keep a total conductance of ten and choose R equal to one tenth. If P equals one, the flow rate is ten; the upstream element then loses one unit of pressure. The overall inlet must be at two so that one unit remains for the branches. Using the value two as if it were directly their pressure drop would have predicted twenty at their outlet, whereas our complete network yields ten.
We can recover the result without trial and error. The upstream pressure must supply P, plus R multiplied by ten P. It therefore equals two P in this particular case. For an upstream pressure of two, P is indeed one. The calculation shows the value of knowing both the measurement point and the portion of the circuit being described. It does not claim to assign a resistance of one tenth to any real machine part.
What happens to this solution if we know only the upstream pressure, without knowing R? Take three imagined readings: two at the overall inlet, ten at the shared outlet, and six in branch A. We no longer include knowledge of P. B still delivers four, but dividing six by the upstream pressure of two would wrongly give gA equal to three: our relation uses the drop across the branches, which remains unknown.
One compatible network is the one we just calculated: P equals one, gA is six, gB is four, and R is one tenth. Let us check a second choice. Take P equal to one half, gA equal to twelve, and gB equal to eight. The flows become twelve times one half and eight times one half—still six and four. To keep two at the overall inlet, the upstream element must lose one and a half units. Since it carries a flow of ten, its resistance must be fifteen hundredths.
The three available pieces of information are identical for both networks. Yet their conductances and branch pressure drops differ. The extra measurement of A did determine the sixty/forty split; it did not determine all the circuit’s parameters. The first calculation had relied on knowing P, which this new situation no longer provides. Keeping the six/four result for the conductances would have smuggled that knowledge back in silently.
The compatible family can even be written out without picking a third example. For any value of P strictly between zero and two, set gA equal to six divided by P and gB equal to four divided by P. Both flows stay six and four. Then choose R equal to two minus P, divided by ten. The upstream element then loses two minus P; adding the branch drop P brings us back to the upstream pressure of two. Every choice in this family matches the same three readings while keeping positive conductances and resistance.
In this idealised problem, knowing the local drop P as well would be enough to resolve the indeterminacy. A value of one would pick the first network; a value of one half would pick the second. The conductances would follow from the two divisions, and R from the difference between upstream pressure and local drop, divided by ten. This example distinguishes two kinds of progress: identifying flow shares and identifying circuit parameters. The first can be achieved while the second remains open.
Proportionality has its limits
The invariance of the flow shares rested on a specific rule. To see what happens when we drop it, keep one path whose flow q equals P and give the other the relation P = q + q²/4. The quadratic term echoes the correction structure discussed by Mo and colleagues; its coefficients and the pairing of the two branches are chosen here. This is not a fit to their data.
For P equal to one, the positive solution for the second path is about 0.828. The first gives one, so it accounts for about 54.7% of the total. For P equal to four, the flows become four and about 2.472. The first path’s share then rises to about 61.8%. We kept the same two relations yet changed the split by changing P. The conclusion from the linear case therefore could not automatically survive this change.
We should not choose between the two examples based on the conclusion we hope to announce. The first allows a proof under proportionality; the second provides a counterexample as soon as another relation is admitted. To describe a real extraction, one would have to determine which assumptions are sufficiently justified, and over what range. Our numbers do not supply that justification.
What this reading allows us to conclude
The primary abstract by Cameron and colleagues, published in 2020, confronts a homogeneous-flow hypothesis with measurements whose yield declines at very fine grinds. The authors see this as an indication of inhomogeneous flow. That passage does not allow diagnosing a specific brew from afar, nor recommending systematically coarsening one’s grind.
Total output and pressure can thus help describe a brew without settling the whole question of its internal flow path. The examples show precisely where an inference stops: at an unknown split between branches, at a condition that was allowed to vary, or at the part of the circuit the measurement does not cover. They offer no automatic conversion between a water split and quality in the cup.
Faced with a number, the next step forward may therefore be a better question: which pressure difference is known, which quantity was counted, and which assumption authorises moving from that measurement to the proposed conclusion? If two descriptions remain compatible with all available information, we can preserve that uncertainty. It is more useful than a certainty achieved by reading into a dial information it never gave.
Sources and method
2017 La Marzocco presentation: passages on the two measurement points. Mo and colleagues, 2023: flow relations. Cameron and colleagues, 2020: abstract accessible prior to manuscript access denial. The full text of the latter was not consulted. Networks, values, and comparisons were constructed for this feature; no hardware trial, machine-modification advice, or tasting result is claimed.
